Tank-W | 10" | 254 mm |
Tank-L | 14" | 355.6 mm |
Tank-H | 8" | 203.2 mm |
Number of Tanks | 4 | 4 |
Transfer System? | No | No |
Dimensions | 86" x 38" x 48" | 86" x 38" x 48" |
Weight | 1,020 lbs | 1,020 lbs |
OC4-1014-HE - Four Stations Optimum Console
Tank Dimensions:
10" left to right by 14" front to back by 10" deep (8" liquid depth).
Overall Dimensions:
80" left to right by 34" front to back by 39" high.
Process: Wash, Rinse, Rinse, Dry.
Chemistry: Deionized Water.
Facilities: 1-3 GPM (4-6 GPM on demand)
DIW@ 1-2 Mohm-cm, 30-35 psi and process temperature,
65-70 CFM CDA @ 30 psi, 1-2 CFM shop air @ 60 psi,
unrestricted floor drain.
Power Requirements: 240 volts/60 Hz/3 phase.
Work Flow: Left to Right.
System Detail:
Station #1:
Ultrasonic Immersion Wash
Maximum Temperature: 160 °F
Ultrasonic Frequency: 40 kHz
Ultrasonic Power: 500 watts of ultrasonic power provided by:
. Six (6) transducer modules direct-bonded to the bottom of the tank.
. One (1) Model 4G-500-40-T ultrasonic generator.
Heat: 2000 watts of strip heat.
Temperature control: Digital indicating temperature controller with a RTD-type temperature probe.
Filtration:
A 5 GPM recirculation/filtration system with:
. One (1) wye strainer.
. One (1) centrifugal, mag-drive pump, with:
o Ryton head.
o Viton o-ring.
o TEFC motor.
. One (1) 10", 10 micron cartridge filter housed in a stainless steel canister.
. One (1) analog pressure gauge.
. Manual flow control valves.
. One (1) recirculation returns surface sparger.
Include a manual bypass line control by manual ball valve.
Standard Features:
. An electronic ultrasonic cycle timer.
. A float-type low liquid level safety.
. A capillary bulb-type overtemperature safety thermostat.
. A basket positioner.
. A stainless steel lift off cover.
. A rear overflow weir plumbed to the recirculation system.
Plumbing:
. Stainless steel compression fittings up to 1" OD.
. Stainless steel threaded pipe ¾" to 1-1/2" wherever necessary.
Station #2:
Ultrasonic Spray-Over-Immersion Rinse
Maximum Temperature: 120 °F
Ultrasonic Frequency: 40 kHz
Ultrasonic Power:
500 watts of ultrasonic power provided by:
. Twelve (6) transducer modules direct-bonded to the bottom of the tank.
. One (1) Model 4G-500-40-T ultrasonic generator.
Heat: 2000 watts of strip heat.
Temperature control:
Digital indicating temperature controller with a RTD-type temperature probe.
Spray rinse:
Stationary spray rinse package, with:
. One (1) set of parallel-opposed spray rinse headers that are:
o Fitted with removable nozzles.
o Located near the top of the tank.
o The solenoid is controlled via a footswitch.
Standard Features:
. An electronic ultrasonic cycle timer.
. A float-type low liquid level safety.
. A capillary bulb-type overtemperature safety thermostat.
. A basket positioner.
. A stainless steel lift off cover.
. A side-located overflow weir plumbed to drain.
Plumbing:
CPVC pipe and fitting for incoming and drain.
Station #3:
Spray-Over-Immersion Rinse
Maximum Temperature: 120 °F
Ultrasonic Frequency: 40 kHz
. Six (6) transducer modules direct-bonded to the bottom of the tank.
. One (1) Model 4G-500-40-T ultrasonic generator.
Heat: 2000 watts of strip heat.
Temperature control:
Digital indicating temperature controller with a RTD-type temperature probe.
Spray rinse:
Stationary spray rinse package, with:
. One (1) set of parallel-opposed spray rinse headers that are:
o Fitted with removable nozzles.
o Located near the top of the tank.
. A solenoid valve on the incoming water line.
o The solenoid is controlled via a footswitch.
Standard Features:
. A float-type low liquid level safety.
. A capillary bulb-type overtemperature safety thermostat.
. A basket positioner.
. A stainless steel lift off cover.
. A side-located overflow baffle with cascade flow to Station #2.
Plumbing:
CPVC pipe and fitting for incoming and drain
Station #4:
High Temperature Recirculating Hot Air Dry
Maximum Temperature: 200F
Heat 5000 watts of heat.
Temperature control: Digital indicating temperature controller with a RTD-type temperature
Blower: An 1100 CFM recirculating blower in the updraft orientation.
Blow-off:
A stationary blow-off package, with:
. One (1) set of parallel-opposed air blow-off headers that are:
o Located near the top of the tank.
. A solenoid valve on the incoming air line.
o The solenoid is controlled via a pushbutton.
. Optional HEPA Filter
Cover:
A manual sliding cover.
Plumbing:
Stainless steel tubing and fittings and brass valves.
System Notes: The general system specifications are as follows:
Tank Material:
Type 316L stainless steel.
Frame Material:
Type 304 stainless steel support frame with leveling legs.
Access Panels:
. Type 304 stainless steel, lift-out access panels on the sides and rear.
. Type 304, stainless steel sliding access doors on the front.
Countertop:
A type 304 stainless steel, removable, countertop. The countertop will be fitted with a 304 stainless steel, removable drainbacks (between the process stations).
Base Plate: A type 304 stainless steel base plate.
Plumbing:
Complete hard plumbed process piping:
. Individual fill and drain connections (at the rear utility panel) will be provided for the wash station.
. Common fill and drain connections (at the rear utility panel) will be provided for the cascade rinse stations.
. All appropriate flow control and isolation ball valves.
Electrical Box:
Single-point electrical connection located in an end-mounted NEMA 12 enclosure.
Shipping dimensions: 86" x 38" x 48" 1,020 lbs
We use cookies to improve your experience. Privacy Policy.
We use different type of cookies to optimize your experience on our website. You may choose which type of cookies to allow and can change your preferences at any time. Remember that disabling cookies may affect your experience on the website. You can learn more about how we cookies by visiting our Privacy Policy.
These cookies are necessary to the core functionality our website and some of its features, such as access to secure areas.
These cookies are used to enhance the performance and functionality of our website but are nonessential. However, without these cookies, certain functionality may become unavailable.
These cookies gather information to help us understand site usage, measure marketing effectiveness, and personalize your experience.
These cookies enhance ad relevance, prevent repeat ads, ensure proper display, and sometimes tailor ads to your interests.